professionalem medicinae

Products

  • Vis et Connection Fastness TEGUMENTUM praevaricationem

    Vis et Connection Fastness TEGUMENTUM praevaricationem

    Product Name: LD-2 Breaking Force and Connection Fastness Tester

  • ZC15811-F Acus Medical Penetration Force Tester

    ZC15811-F Acus Medical Penetration Force Tester

    Probator 5.7-inch color tactus screen ut menus ostendat: nomial extra diametrum acus, genus muri Tubing, test, tempora test, flumine, amni, tempore et standardisationi.maximam vim acuminis ac virium apicem quinque (ie F0, F1, F2, F3 et F4) ostendit in tempore reali, et -in typographo constructum famam imprimere potest.
    Murus Tubing: murus ordinarius, murus tenuis, vel murus tenuis extra libitum est
    Nominales extra diametrum acus: 0.2mm ~1.6mm
    Load Capacity: 0N~5N, subtiliter ±0.01N.
    Motus velocitatis: 100mm/min
    Cutis Substitutus: Polyurethane foil obsecundans cum GB 15811-2001

  • ZG9626-F Examen Medical (Tubing) rigor Tester

    ZG9626-F Examen Medical (Tubing) rigor Tester

    Probator a PLC refrenat, et color 5.7 digiti tactus velum ad menus demonstrandum adhibet: signata mensura metrica Tubingae, genus muri Tubing, palmi, vis flexionis, deflexio maxima, impressio setup, test, adverso flumine, amni, tempore et standardisation, ac bulit -in printer can print the test report.
    Murus Tubing: murus ordinarius, murus tenuis, vel murus tenuis extra libitum est.
    Tubingae magnitudo metrica designata: 0.2mm ~4.5mm
    vis flexionis: 5.5N~60N, accuratione ± 0.1N.
    Velocitas onus: adhibere deorsum ad rate of 1mm/min ad Tubing inflexionis determinatum vim
    Spatio: 5mm~ 50mm (11 specifications ) cum accuratione ± 0.1mm
    Declinatio test: 0~0.8mm cum accuratione ±0.01mm

  • ZR9626-D Acus Medical (Tubing) Repugnantia Breakage Tester

    ZR9626-D Acus Medical (Tubing) Repugnantia Breakage Tester

    Probator 5.7 inch colorem LCD ad menus demonstrandum adoptat: genus muri Tubing, angulum flexionis, signatum, magnitudinem Tubingae metricam, distantiam inter sustentationem rigidam et punctum applicationis vis inflexionis, et numerus cyclorum inflexionum, PLC cognoscit programma setup quae efficit probationes ipso facto.
    Murus Tubing: murus ordinarius, murus tenuis, vel murus tenuis extra libitum est
    Magnitudo metrica designata tubing: 0.05mm~4.5mm
    Frequentia sub test: 0.5Hz
    Angulus inflexus: 15° , 20° et 25° .
    Inclinatio distantiae: subtiliter ± 0.1mm;
    Circulorum numerus: in unam partem plicare Tubing, deinde in contrariam partem;

  • ZF15810-D Medical Syringe Air Leakage Tester

    ZF15810-D Medical Syringe Air Leakage Tester

    Pressura negativa test: lectio manometri 88kpa ictu pressionis atmosphaerici ambientis ventum est;error: intra ±0.5kpa;Cum DUXERIT digital ostentationem
    Tempus probationis: adaptabile ab 1secundo ad 10 minutos;intus DUXERIT digital propono.
    (Instantia negativa lectio in manometro exhibita ±0,5kpa pro 1 momento non mutabitur.)

  • ZH15810-D Medical Syringe Illapsum Tester

    ZH15810-D Medical Syringe Illapsum Tester

    Tester utitur 5.7-inch color tactus screen ut menus monstret, In usu PLC controls, capacitas nominalis syringae seligi potest;velum percipere potest tempus reale ostensionis virium ad motum praeceps incipiendum, vim mediam in reditu ductoris, vim maximam et minimam in reditu descensu, et graphi virium ad praeceptorem operandum;eventus test statim provisum est et constructum -in typographo famam testam imprimere potest.

    Load Capacity : ;error: 1N~40N error: intra ± 0.3N
    Test Velocitas: (100±5)mm/min
    Facultas nominalis syringae: selectabilis ab 1ml ad 60ml.

    omnes non mutantur ±0.5kpa pro 1 momento.)

  • ZZ15810-D Syringe Liquid Leakage Tester

    ZZ15810-D Syringe Liquid Leakage Tester

    Probator 5.7-inch color tactum screen ad ostendendum menus: capacitatem nominalem syringae, vim et axialem pressionem pro lacus testandi, et durationem applicandi vim ad praeceps, et constructum - apud typographum famam test imprimere potest.PLC machinam humanam conversationis et tactus veli ostentationis moderatur.
    1.Product Name: Medical Syring Testing Equipment
    2.Side vis: 0.25N~3N;errorem: intra ± V%
    3.Axial pressura: 100kpa~400kpa;errorem: intra ± V%
    4.Nominal facultatem clysterem: selectable ex 1ml ad 60ml
    5.Time tentationis: 30S;errorem: intra ± 1s

  • ZD1962-T Conical Fittings with a 6% Luer Taper Multipurpose Tester

    ZD1962-T Conical Fittings with a 6% Luer Taper Multipurpose Tester

    Testor in PLC controls nititur et 5.7 digiti coloris tactus screen ut ostenderet menus, operatores uti possunt claves tactus ad eligendam capacitatem nomicam clysterem vel nominalem extra diametrum acus sicut per productum specificationem.Vis axialis , torques, tempus tenent, vis pressionis hydraulica et eparationis vis in experimento exponi potest, probator liquidum lacus, aerem lacus, vim separationis, torques unscrewing, otium conventus, resistentia summopere et accentus crepuit conici (clausum. ) congruens cum 6% cereis pro syringis, acus et quibusdam aliis instrumentis medicis, ut infusione copia, transfusio, infusio acus, fistulae, filtra pro anesthescia, etc. constructum - typis imprimi potest fama probata.

  • YM-B Air Leakage Tester enim Medical machinae

    YM-B Air Leakage Tester enim Medical machinae

    TEGUMENTUM specialiter adhibetur pro calculi aeris experimentis ad medicinae machinas, applicabilis ad infusionem copiae, transfusionis copiae, infusionis acus, percolationes pro anesthesia, tubinga, cathetera, juncturas velox, etc.
    Teli pressionis output: stabilis ab 20kpa ad 200kpa super loci atmosphaericis pressionis, cum ducatur digital propono;error: intra ± 2.5% lectionis
    Duratio : 5 seconds ~ 99.9 minuta;cum DUXERIT digitalis proponere;errorem: intra ± 1s

  • SY-B Insufion Pump Flow Rate Tester

    SY-B Insufion Pump Flow Rate Tester

    Probator designatur et fabricatur secundum novissimam editionem YY0451 "Unum usum injectiorum ad continuam administrationem ambulatoriae rei medicae per viam parentalem" et ISO/DIS 28620 "medicinae machinae infusiones portatiles non electricae eiectae".Potest probare medium fluere rate et momentaneum fluere rate octo infusione soleatus simul et proponere curvam ratem uniuscuiusque sentinae infusionis.
    Probator ex PLC controls nititur et tactus screen ut menus monstrat.Operatores uti possunt clavium tactum ad eligendum parametros examinis et experimentum automatice cognoscendi.Et constructum-in typographo probationem famae imprimere potest.
    Resolutio: 0.01g;error: in ± I% lectionis

  • YL-D Medical Fabrica O Rate Tester

    YL-D Medical Fabrica O Rate Tester

    TEGUMENTUM designatur secundum signa nationalia et specialiter adhibita ad probandum rate de medicorum machinis fluxus.
    Teli pressionis output: stabilis ab 10kPa ad 300kPa supra loaca atmosphaerica pressione, cum ostentatione digitali DUXERIT, error: intra ±2.5% lectionis.
    Duratio: 5 seconds ~ 99.9 minuta, intra digital ostentationem, errorem: intra ±1s.
    Locus applicabilis ad infusionem occidit, transfusio occidit, infusio acus, cathetera, filtra pro anesthesia, etc.

  • DF-0174A Ferrum chirurgicum Tester acumen

    DF-0174A Ferrum chirurgicum Tester acumen

    Probator designatur et fabricatur secundum YY0174-2005 "ensem scalpelli".Maxime ad probandum acumen chirurgicum ferrum.Vim demonstrat requisitam ad suturas chirurgicae secandas et maximam vim incisionis in tempore reali.
    Constat ex PLC, velum tactu, vi mensurae unitatis, transmissionis unitatis, typographi, etc. Facile est operari et clare ostendit.Et bene voltus summa cura ac constantia.
    Vis metiendi range: 0~15N;resolutio: 0.001N;error: intra ± 0.01N
    Test celeritas: 600mm ± 60mm/min